Driver Parameters:
 reserve_mode: 	1         	reserve_list:  	--
 max_ids:      	127       	hdr_channel:   	0

Disk Array Controller Information:
 Number:       	0         	Name:          	SRCU42L
 Driver Ver.:  	3.04      	Firmware Ver.: 	2.34.09-R05C
 Serial No.:   	0x39C032D0	Cache RAM size:	65536 KB

Physical Devices:
 Chn/ID/LUN:   	B/06/0    	Name:          	ESG-SHV SCA HSBP M16    0.05
 Capacity [MB]:	0         	To Log. Drive: 	--

 Chn/ID/LUN:   	B/00/0    	Name:          	SEAGATE ST373207LC      0005
 Capacity [MB]:	69974     	To Log. Drive: 	0
 Retries:      	1         	Reassigns:     	0
 Grown Defects:	0

 Chn/ID/LUN:   	B/01/0    	Name:          	MAXTOR  ATLAS10K4_73SCA DFL0
 Capacity [MB]:	70116     	To Log. Drive: 	1
 Retries:      	7         	Reassigns:     	0
 Grown Defects:	0

 Chn/ID/LUN:   	B/02/0    	Name:          	MAXTOR  ATLAS10K5_73SCA JNZH
 Capacity [MB]:	70116     	To Log. Drive: 	2
 Retries:      	1         	Reassigns:     	0
 Grown Defects:	0

 Chn/ID/LUN:   	B/03/0    	Name:          	SEAGATE ST373207LC      0005
 Capacity [MB]:	69974     	To Log. Drive: 	3
 Retries:      	1         	Reassigns:     	0
 Grown Defects:	0

 Chn/ID/LUN:   	B/04/0    	Name:          	SEAGATE ST373207LC      0005
 Capacity [MB]:	69974     	To Log. Drive: 	4
 Retries:      	1         	Reassigns:     	0
 Grown Defects:	0

 Chn/ID/LUN:   	B/05/0    	Name:          	FUJITSU MAX3147NC       0104
 Capacity [MB]:	140239    	To Log. Drive: 	5
 Retries:      	1         	Reassigns:     	0
 Grown Defects:	1

Logical Drives:
 Number:       	0         	Status:        	ok
 Capacity [MB]:	69974     	Type:          	Disk
 To Array Drv.:	0

 Number:       	1         	Status:        	ok
 Capacity [MB]:	69974     	Type:          	Disk
 To Array Drv.:	0

 Number:       	2         	Status:        	ok
 Capacity [MB]:	69974     	Type:          	Disk
 To Array Drv.:	0

 Number:       	3         	Status:        	ok
 Capacity [MB]:	69974     	Type:          	Disk
 To Array Drv.:	0

 Number:       	4         	Status:        	ok
 Capacity [MB]:	69974     	Type:          	Disk
 To Array Drv.:	0

 Number:       	5         	Status:        	ok
 Capacity [MB]:	69974     	Type:          	Disk
 To Array Drv.:	0

Array Drives:
 Number:       	0         	Status:        	fail
 Capacity [MB]:	349872    	Type:          	RAID-5

Host Drives:
 Number:       	0         	Arr/Log. Drive:	0
 Capacity [MB]:	349860    	Start Sector:  	8192

Controller Events:
 date- 1262:02:58	Adapter 0: Bus B: The SCSI controller successfully recovered from a SCSI BUS issue.  The issue may still be present on the BUS.  Check cables, termination, termpower, LVDS operation, etc

 date- 1262:02:58	Adapter 0: SCSI-B, ID 1: MPI returned 0x00000048

 date- 481:50:49	Adapter 0: SCSI-B, ID 1: MPI returned 0x00000002

 date- 481:50:46	Adapter 0: SCSI-B, ID 1: last status 0x29047006. Sense code: UNIT ATTENTION, DEVICE INTERNAL RESET

 date- 481:50:46	Adapter 0: SCSI-B, ID 1: Check cables, termination, termpower, LVDS operation, etc.

 date- 481:50:46	Adapter 0: Array Drive 0: Logical Drive 1 <SCSI-B, ID 1, LUN 0> failed

 date- 481:50:47	Adapter 0: Array Drive 0: FAIL state entered

 date- 481:50:47	Adapter 0: SCSI-B, ID 1: Auto Hot Plug started for slot 1