.SS temperature temperature12
.I read-only, floating point
.br
.I Temperature
read by the chip at high resolution (~12 bits). Units are selected from the invoking command line. See
.B owfs(5)
for choices. Default is Celsius.
.br
Conversion takes 1000 msec.
.SS temperature11
.I read-only, floating point
.br
.I Temperature
read by the chip at moderate resolution (11 bits). Units are selected from the invoking command line. See
.B owfs(5)
for choices. Default is Celsius.
.br
Conversion takes 400 msec.
.SS temperature10
.I read-only, floating point
.br
.I Temperature
read by the chip at moderate resolution (10 bits). Units are selected from the invoking command line. See
.B owfs(5)
for choices. Default is Celsius.
.br
Conversion takes 200 msec.
.SS temperature9 fasttemp
.I read-only, floating point
.br
.I Temperature
read by the chip at low resolution (9 bits). Units are selected from the invoking command line. See
.B owfs(5)
for choices. Default is Celsius.
.br
Conversion takes 110 msec.